#General information ITEM section %ITEM SERIAL NUMBER 20220900208909 Mfr serial number STN12635-08909 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 26/03/2002 PROBLEM NO PASSED YES Run number 20220900208909 #Test data Data section %DATA TEMPERATURE (C) 27 I_LEAK150V (microA) 0.12336 I_LEAK350V (microA) 0.1861 Substr Origin 244 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 290 Vdep (V) 75 R Bias Upper (MOhm) 1.44 R Bias Lower (MOhm) 1.33 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 39.98 20 54.34 30 62.62 40 69.15 50 74.79 60 80.32 70 85.81 80 91.44 90 96.8 100 101.84 110 106.57 120 111.04 130 115.32 140 119.41 150 123.36 160 127.2 170 130.8 180 134.42 190 137.93 200 141.38 210 144.74 220 148.03 230 151.26 240 154.43 250 157.54 260 160.58 270 163.51 280 166.5 290 169.38 300 172.21 310 175.05 320 177.84 330 180.7 340 183.4 350 186.1 #CV 10 15 O.L. 20 O.L. 25 2901.26 30 2502.51 35 2223.13 40 2012.69 45 1851.22 50 1721.18 55 1616.25 60 1534.91 65 1478.21 70 1443.56 75 1425 80 1415.74 85 1411.3 90 1408.87 95 1407.26 100 1405.89 105 1404.77 110 1403.83 115 1403.07 120 1402.33 #End of manufacturer data file