#General information ITEM section %ITEM SERIAL NUMBER 20220900208910 Mfr serial number STN12635-08910 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 26/03/2002 PROBLEM NO PASSED YES Run number 20220900208910 #Test data Data section %DATA TEMPERATURE (C) 27 I_LEAK150V (microA) 0.12852 I_LEAK350V (microA) 0.1944 Substr Origin 244 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 290 Vdep (V) 75 R Bias Upper (MOhm) 1.44 R Bias Lower (MOhm) 1.33 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 40.04 20 54.78 30 63.3 40 70.02 50 75.91 60 82.01 70 88.3 80 94.47 90 100.23 100 105.61 110 110.62 120 115.37 130 119.9 140 124.28 150 128.52 160 132.54 170 136.47 180 140.33 190 144.06 200 147.77 210 151.34 220 154.87 230 158.3 240 161.69 250 164.93 260 168.13 270 171.17 280 174.23 290 177.22 300 180.3 310 183.2 320 186.1 330 188.9 340 191.7 350 194.4 #CV 10 15 O.L. 20 O.L. 25 2876.65 30 2482.8 35 2206.97 40 1999.5 45 1840.07 50 1711.61 55 1608.12 60 1528.83 65 1475.22 70 1443.63 75 1427.25 80 1419.3 85 1415.22 90 1412.78 95 1411.2 100 1410.01 105 1408.89 110 1407.87 115 1407.18 120 1406.47 #End of manufacturer data file