#General information ITEM section %ITEM SERIAL NUMBER 20220900209086 Mfr serial number STN12761-09086 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 16/04/2002 PROBLEM NO PASSED YES Run number 20220900209086 #Test data Data section %DATA TEMPERATURE (C) 27 I_LEAK150V (microA) 0.08874 I_LEAK350V (microA) 0.12645 Substr Origin 261 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 291 Vdep (V) 75 R Bias Upper (MOhm) 1.6 R Bias Lower (MOhm) 1.41 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 34.41 20 43.87 30 49.85 40 54.65 50 58.58 60 61.99 70 65.34 80 68.85 90 72.29 100 75.49 110 78.43 120 81.2 130 83.82 140 86.31 150 88.74 160 91.04 170 93.27 180 95.45 190 97.56 200 99.67 210 101.66 220 103.65 230 105.61 240 107.52 250 109.39 260 111.23 270 113 280 114.75 290 116.52 300 118.25 310 119.95 320 121.62 330 123.24 340 124.88 350 126.45 #CV 10 15 O.L. 20 O.L. 25 2917.74 30 2517.3 35 2236.93 40 2026.37 45 1864.34 50 1734.92 55 1630.86 60 1550.52 65 1492.73 70 1455.18 75 1432.88 80 1420.51 85 1414.08 90 1410.66 95 1408.6 100 1407.18 105 1406.07 110 1405.18 115 1404.54 120 1403.63 #End of manufacturer data file