#General information ITEM section %ITEM SERIAL NUMBER 20220900209118 Mfr serial number STN12762-09118 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 16/04/2002 PROBLEM NO PASSED YES Run number 20220900209118 #Test data Data section %DATA TEMPERATURE (C) 27 I_LEAK150V (microA) 0.11888 I_LEAK350V (microA) 0.17436 Substr Origin 249 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 289 Vdep (V) 75 R Bias Upper (MOhm) 1.45 R Bias Lower (MOhm) 1.2 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 41.26 20 54.08 30 62.35 40 69.12 50 74.91 60 80.08 70 85.18 80 90.23 90 95.12 100 99.69 110 103.9 120 107.92 130 111.71 140 115.36 150 118.88 160 122.25 170 125.5 180 128.67 190 131.79 200 134.84 210 137.77 220 140.74 230 143.6 240 146.42 250 149.2 260 151.92 270 154.48 280 157.12 290 159.72 300 162.29 310 164.8 320 167.26 330 169.7 340 172.04 350 174.36 #CV 10 15 O.L. 20 O.L. 25 2899.32 30 2497.44 35 2215.53 40 2004.58 45 1842.43 50 1713.89 55 1612.96 60 1537.45 65 1485.28 70 1452.73 75 1434.4 80 1424.95 85 1420.18 90 1417.52 95 1415.78 100 1414.57 105 1413.56 110 1412.69 115 1412 120 1411.28 #End of manufacturer data file