#General information ITEM section %ITEM SERIAL NUMBER 20220900209208 Mfr serial number STN12766-09208 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 16/04/2002 PROBLEM NO PASSED YES Run number 20220900209208 #Test data Data section %DATA TEMPERATURE (C) 27 I_LEAK150V (microA) 0.10839 I_LEAK350V (microA) 0.16016 Substr Origin 251 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 290 Vdep (V) 70 R Bias Upper (MOhm) 1.67 R Bias Lower (MOhm) 1.44 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 36.1 20 49.15 30 56.4 40 62.19 50 67.31 60 71.93 70 76.77 80 81.58 90 86.16 100 90.32 110 94.34 120 98.06 130 101.69 140 105.1 150 108.39 160 111.55 170 114.7 180 117.7 190 120.6 200 123.42 210 126.26 220 128.95 230 131.62 240 134.23 250 136.79 260 139.39 270 141.9 280 144.34 290 146.74 300 149.15 310 151.44 320 153.68 330 155.86 340 158.05 350 160.16 #CV 10 15 O.L. 20 O.L. 25 2823.83 30 2434.41 35 2160.38 40 1956.76 45 1799.4 50 1675.2 55 1579.27 60 1511.11 65 1467.07 70 1441.74 75 1428.19 80 1421.17 85 1417.68 90 1415.53 95 1414.03 100 1413 105 1412 110 1411.17 115 1410.48 120 1409.85 #End of manufacturer data file