#General information ITEM section %ITEM SERIAL NUMBER 20220900209239 Mfr serial number STN12766-09239 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 16/04/2002 PROBLEM NO PASSED YES Run number 20220900209239 #Test data Data section %DATA TEMPERATURE (C) 27 I_LEAK150V (microA) 0.09485 I_LEAK350V (microA) 0.13662 Substr Origin 251 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 289 Vdep (V) 75 R Bias Upper (MOhm) 1.67 R Bias Lower (MOhm) 1.44 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole 21 Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 33.23 20 44.97 30 51.42 40 56.38 50 60.67 60 64.89 70 68.93 80 72.84 90 76.58 100 80.04 110 83.3 120 86.3 130 89.34 140 92.09 150 94.85 160 97.38 170 99.95 180 102.43 190 104.79 200 107.12 210 109.43 220 111.65 230 113.8 240 115.92 250 118.02 260 120.08 270 122.12 280 124.11 290 126.02 300 127.93 310 129.7 320 131.49 330 133.17 340 134.99 350 136.62 #CV 10 15 O.L. 20 O.L. 25 2869.55 30 2473.26 35 2194.91 40 1987.84 45 1827.76 50 1701.01 55 1602.17 60 1529.62 65 1480.75 70 1451.27 75 1435.22 80 1426.91 85 1422.64 90 1420.14 95 1418.54 100 1417.31 105 1416.32 110 1415.56 115 1414.71 120 1414.09 #End of manufacturer data file