#General information ITEM section %ITEM SERIAL NUMBER 20220900209240 Mfr serial number STN12766-09240 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 16/04/2002 PROBLEM NO PASSED YES Run number 20220900209240 #Test data Data section %DATA TEMPERATURE (C) 27 I_LEAK150V (microA) 0.09284 I_LEAK350V (microA) 0.13464 Substr Origin 251 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 289 Vdep (V) 70 R Bias Upper (MOhm) 1.67 R Bias Lower (MOhm) 1.44 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 32.32 20 43.69 30 49.92 40 54.72 50 58.85 60 62.93 70 66.95 80 70.87 90 74.62 100 78.11 110 81.32 120 84.38 130 87.37 140 90.15 150 92.84 160 95.43 170 98 180 100.42 190 102.79 200 105.1 210 107.43 220 109.62 230 111.77 240 113.87 250 115.95 260 118.04 270 120.05 280 122.02 290 123.94 300 125.89 310 127.72 320 129.46 330 131.18 340 132.96 350 134.64 #CV 10 15 O.L. 20 O.L. 25 2840.49 30 2448.4 35 2173.7 40 1968.69 45 1810.45 50 1685 55 1587.23 60 1516.22 65 1469.85 70 1443.06 75 1429.06 80 1422.05 85 1418.41 90 1416.24 95 1414.75 100 1413.57 105 1412.59 110 1411.73 115 1410.92 120 1410.29 #End of manufacturer data file