#General information ITEM section %ITEM SERIAL NUMBER 20220900209309 Mfr serial number STN12772-09309 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 22/04/2002 PROBLEM NO PASSED YES Run number 20220900209309 #Test data Data section %DATA TEMPERATURE (C) 27 I_LEAK150V (microA) 0.12341 I_LEAK350V (microA) 0.1813 Substr Origin 256 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 290 Vdep (V) 80 R Bias Upper (MOhm) 1.42 R Bias Lower (MOhm) 1.36 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 40.13 20 55.87 30 64.78 40 72.17 50 78.84 60 84.71 70 89.81 80 94.67 90 99.37 100 103.86 110 108.14 120 112.19 130 116.06 140 119.78 150 123.41 160 126.91 170 130.33 180 133.65 190 136.93 200 140.11 210 143.27 220 146.38 230 149.32 240 152.22 250 155.09 260 157.93 270 160.67 280 163.43 290 165.91 300 168.68 310 171.3 320 173.84 330 176.39 340 178.92 350 181.3 #CV 10 15 O.L. 20 O.L. 25 O.L. 30 2662.13 35 2358.65 40 2133.52 45 1958.68 50 1819.22 55 1705.12 60 1612.9 65 1541.25 70 1490.05 75 1456.86 80 1436.86 85 1425.56 90 1419.5 95 1416.15 100 1414.05 105 1412.73 110 1411.69 115 1410.86 120 1410.03 #End of manufacturer data file