#General information ITEM section %ITEM SERIAL NUMBER 20220900209322 Mfr serial number STN12781-09322 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 22/04/2002 PROBLEM NO PASSED YES Run number 20220900209322 #Test data Data section %DATA TEMPERATURE (C) 27 I_LEAK150V (microA) 0.1289 I_LEAK350V (microA) 0.191 Substr Origin 273 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 290 Vdep (V) 75 R Bias Upper (MOhm) 1.46 R Bias Lower (MOhm) 1.25 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole 405 Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 40.51 20 56.34 30 66.46 40 74.12 50 80.61 60 86.73 70 92.36 80 97.65 90 102.72 100 107.54 110 112.22 120 116.62 130 120.86 140 124.95 150 128.9 160 132.73 170 136.43 180 140.09 190 143.63 200 147.06 210 150.47 220 153.73 230 157.03 240 160.18 250 163.27 260 166.1 270 169.3 280 172.16 290 175.04 300 177.82 310 180.4 320 183.2 330 185.9 340 188.4 350 191 #CV 10 15 O.L. 20 O.L. 25 2881.09 30 2480.71 35 2199.99 40 1994.2 45 1833.61 50 1706.03 55 1604.69 60 1529.09 65 1477.37 70 1445.45 75 1427.59 80 1418.07 85 1413.42 90 1411.04 95 1409.48 100 1408.21 105 1407.34 110 1406.48 115 1405.67 120 1405.08 #End of manufacturer data file