#General information ITEM section %ITEM SERIAL NUMBER 20220900209402 Mfr serial number STN12642-09402 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 24/04/2002 PROBLEM NO PASSED YES Run number 20220900209402 #Test data Data section %DATA TEMPERATURE (C) 27 I_LEAK150V (microA) 0.13413 I_LEAK350V (microA) 0.1974 Substr Origin 249 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 287 Vdep (V) 75 R Bias Upper (MOhm) 1.75 R Bias Lower (MOhm) 1.39 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 43.36 20 60.29 30 70.11 40 78.15 50 84.75 60 90.51 70 96.17 80 101.9 90 107.41 100 112.51 110 117.28 120 121.77 130 125.94 140 130.15 150 134.13 160 138.01 170 141.74 180 145.4 190 148.97 200 152.43 210 155.88 220 159.18 230 162.43 240 165.65 250 168.8 260 171.9 270 174.96 280 177.96 290 180.8 300 183.7 310 186.5 320 189.3 330 192.1 340 194.8 350 197.4 #CV 10 15 O.L. 20 O.L. 25 2919.3 30 2513.36 35 2228.89 40 2017.63 45 1853.85 50 1724.58 55 1622.27 60 1546.82 65 1494.97 70 1462.95 75 1445.06 80 1436.07 85 1431.62 90 1428.87 95 1427.43 100 1425.95 105 1425.14 110 1424.26 115 1423.61 120 1422.97 #End of manufacturer data file