#General information ITEM section %ITEM SERIAL NUMBER 20220900209861 Mfr serial number STN12912-09861 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 22/05/2002 PROBLEM NO PASSED YES Run number 20220900209861 #Test data Data section %DATA TEMPERATURE (C) 29 I_LEAK150V (microA) 0.17141 I_LEAK350V (microA) 0.2606 Substr Origin 261 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 291 Vdep (V) 70 R Bias Upper (MOhm) 1.64 R Bias Lower (MOhm) 1.46 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 53.33 20 75.32 30 87.59 40 97.16 50 105.64 60 113.38 70 120.92 80 128.37 90 135.48 100 142.17 110 148.43 120 154.45 130 160.38 140 165.96 150 171.41 160 176.69 170 182.1 180 187.1 190 192 200 196.8 210 201.6 220 206.2 230 210.7 240 215.1 250 219.5 260 224 270 228.3 280 232.5 290 236.6 300 240.8 310 244.9 320 248.6 330 252.8 340 256.8 350 260.6 #CV 10 15 O.L. 20 O.L. 25 2764.06 30 2381.93 35 2114.98 40 1913.28 45 1760.59 50 1640.6 55 1551 60 1490.2 65 1452.78 70 1431.48 75 1420.21 80 1414.41 85 1411.31 90 1409.27 95 1407.83 100 1406.66 105 1405.68 110 1404.84 115 1404.07 120 1403.25 #End of manufacturer data file