#General information ITEM section %ITEM SERIAL NUMBER 20220900209868 Mfr serial number STN12912-09868 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 22/05/2002 PROBLEM NO PASSED YES Run number 20220900209868 #Test data Data section %DATA TEMPERATURE (C) 29 I_LEAK150V (microA) 0.17715 I_LEAK350V (microA) 0.2734 Substr Origin 261 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 289 Vdep (V) 70 R Bias Upper (MOhm) 1.64 R Bias Lower (MOhm) 1.46 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 54.22 20 76.68 30 89.56 40 99.58 50 108.13 60 116.34 70 124.49 80 132.33 90 139.73 100 146.67 110 153.17 120 159.43 130 165.58 140 171.44 150 177.15 160 182.5 170 188.2 180 193.4 190 198.7 200 203.7 210 208.9 220 213.9 230 218.6 240 223.6 250 228.5 260 233.4 270 238.5 280 243 290 247 300 251.9 310 256.2 320 260.5 330 264.8 340 268.9 350 273.4 #CV 10 15 O.L. 20 O.L. 25 2810.47 30 2420.42 35 2148.12 40 1943.07 45 1786.99 50 1663.85 55 1570.65 60 1505.62 65 1464.37 70 1440.5 75 1427.53 80 1420.8 85 1417.25 90 1415.12 95 1413.6 100 1412.43 105 1411.41 110 1410.52 115 1409.84 120 1409 #End of manufacturer data file