#General information ITEM section %ITEM SERIAL NUMBER 20220900209914 Mfr serial number STN12942-09914 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 24/05/2002 PROBLEM NO PASSED YES Run number 20220900209914 #Test data Data section %DATA TEMPERATURE (C) 28 I_LEAK150V (microA) 0.12206 I_LEAK350V (microA) 0.1812 Substr Origin 260 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 290 Vdep (V) 70 R Bias Upper (MOhm) 1.55 R Bias Lower (MOhm) 1.44 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 40.27 20 55.6 30 64.11 40 70.81 50 77.2 60 82.7 70 87.85 80 92.88 90 97.74 100 102.29 110 106.62 120 110.72 130 114.65 140 118.42 150 122.06 160 125.62 170 129.06 180 132.42 190 135.72 200 138.92 210 142.08 220 145.2 230 148.07 240 151.24 250 154.18 260 157.08 270 159.95 280 162.77 290 165.57 300 168.31 310 170.9 320 173.47 330 176.14 340 178.73 350 181.2 #CV 10 15 O.L. 20 O.L. 25 2775.95 30 2389.99 35 2117.25 40 1917.36 45 1764.34 50 1644.31 55 1553.37 60 1489.42 65 1448.84 70 1425.57 75 1413.32 80 1407.36 85 1404.35 90 1402.57 95 1401.28 100 1400.28 105 1399.39 110 1398.68 115 1398.12 120 1397.5 #End of manufacturer data file