#General information ITEM section %ITEM SERIAL NUMBER 20220900210030 Mfr serial number STN12914-10030 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 28/05/2002 PROBLEM NO PASSED YES Run number 20220900210030 #Test data Data section %DATA TEMPERATURE (C) 27 I_LEAK150V (microA) 0.09384 I_LEAK350V (microA) 0.13538 Substr Origin 262 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 292 Vdep (V) 75 R Bias Upper (MOhm) 1.46 R Bias Lower (MOhm) 1.31 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 32.97 20 44.55 30 50.91 40 55.9 50 60.25 60 64.27 70 68.14 80 72.01 90 75.74 100 79.23 110 82.46 120 85.51 130 88.4 140 91.18 150 93.84 160 96.43 170 98.85 180 101.27 190 103.61 200 105.91 210 108.16 220 110.3 230 112.47 240 114.59 250 116.65 260 118.67 270 120.65 280 122.64 290 124.59 300 126.51 310 128.37 320 130.16 330 131.94 340 133.69 350 135.38 #CV 10 15 O.L. 20 O.L. 25 2962.03 30 2551.74 35 2264.09 40 2048.05 45 1882.73 50 1749.57 55 1642.02 60 1557.54 65 1496.35 70 1455.92 75 1431.58 80 1417.97 85 1410.88 90 1407.03 95 1404.8 100 1403.25 105 1402.12 110 1401.29 115 1400.46 120 1399.79 #End of manufacturer data file