#General information ITEM section %ITEM SERIAL NUMBER 20220900210082 Mfr serial number STN12918-10082 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 05/06/2002 PROBLEM NO PASSED YES Run number 20220900210082 #Test data Data section %DATA TEMPERATURE (C) 27 I_LEAK150V (microA) 0.12661 I_LEAK350V (microA) 0.1847 Substr Origin 263 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 290 Vdep (V) 75 R Bias Upper (MOhm) 1.56 R Bias Lower (MOhm) 1.46 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 42.82 20 59.07 30 67.91 40 74.93 50 80.91 60 86.41 70 91.77 80 97.03 90 102.01 100 106.69 110 111.04 120 115.17 130 119.13 140 122.93 150 126.61 160 130.16 170 133.54 180 136.91 190 140.15 200 143.35 210 146.48 220 149.53 230 152.53 240 155.48 250 158.36 260 161.22 270 163.93 280 166.58 290 169.39 300 172.08 310 174.71 320 177.29 330 179.81 340 182.4 350 184.7 #CV 10 15 O.L. 20 O.L. 25 2881.5 30 2483.6 35 2205.86 40 1996.17 45 1835.42 50 1707.78 55 1606.84 60 1532.07 65 1480.92 70 1449.59 75 1432.12 80 1423.13 85 1418.35 90 1415.9 95 1414.12 100 1412.77 105 1411.68 110 1410.91 115 1410.16 120 1409.47 #End of manufacturer data file