#General information ITEM section %ITEM SERIAL NUMBER 20220900210200 Mfr serial number STN12924-10200 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 05/06/2002 PROBLEM NO PASSED YES Run number 20220900210200 #Test data Data section %DATA TEMPERATURE (C) 27 I_LEAK150V (microA) 0.15814 I_LEAK350V (microA) 0.2415 Substr Origin 264 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 289 Vdep (V) 75 R Bias Upper (MOhm) 1.56 R Bias Lower (MOhm) 1.42 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 46.45 20 65.87 30 77.06 40 86 50 93.97 60 101.64 70 108.96 80 116.14 90 123.11 100 129.7 110 135.96 120 141.9 130 147.55 140 152.9 150 158.14 160 163.24 170 168.13 180 172.99 190 177.62 200 182.1 210 186.6 220 190.9 230 195 240 199.4 250 203.5 260 207.6 270 211.6 280 215.5 290 219.4 300 223.2 310 226.9 320 230.6 330 234.3 340 237.9 350 241.5 #CV 10 15 O.L. 20 O.L. 25 2999 30 2583.12 35 2292.12 40 2073.5 45 1904.64 50 1770.1 55 1661.35 60 1576.27 65 1513.35 70 1471.09 75 1445.36 80 1430.66 85 1422.92 90 1418.79 95 1416.28 100 1414.61 105 1413.45 110 1412.54 115 1411.71 120 1410.99 #End of manufacturer data file