#General information ITEM section %ITEM SERIAL NUMBER 20220900210246 Mfr serial number STN12921-10246 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 17/06/2002 PROBLEM NO PASSED YES Run number 20220900210246 #Test data Data section %DATA TEMPERATURE (C) 27 I_LEAK150V (microA) 0.11176 I_LEAK350V (microA) 0.163 Substr Origin 267 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 292 Vdep (V) 80 R Bias Upper (MOhm) 1.54 R Bias Lower (MOhm) 1.48 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 36.78 20 51.65 30 59.72 40 65.94 50 71.12 60 75.83 70 80.44 80 85.03 90 89.6 100 93.91 110 97.9 120 101.68 130 105.19 140 108.51 150 111.76 160 114.9 170 117.91 180 120.87 190 123.76 200 126.52 210 129.25 220 131.9 230 134.59 240 137.15 250 139.68 260 142.19 270 144.59 280 146.99 290 149.38 300 151.72 310 154 320 156.32 330 158.59 340 160.81 350 163 #CV 10 15 O.L. 20 O.L. 25 O.L. 30 2588.13 35 2295.69 40 2077.38 45 1907.91 50 1773.54 55 1664.66 60 1578.73 65 1513.84 70 1468.6 75 1439.81 80 1422.63 85 1413.22 90 1408.31 95 1405.46 100 1403.7 105 1402.37 110 1401.44 115 1400.58 120 1399.67 #End of manufacturer data file