#General information ITEM section %ITEM SERIAL NUMBER 20220900210402 Mfr serial number STN12929-10402 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 17/06/2002 PROBLEM NO PASSED YES Run number 20220900210402 #Test data Data section %DATA TEMPERATURE (C) 27 I_LEAK150V (microA) 0.14857 I_LEAK350V (microA) 0.2255 Substr Origin 263 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 290 Vdep (V) 70 R Bias Upper (MOhm) 1.56 R Bias Lower (MOhm) 1.41 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 45.95 20 64.58 30 75.06 40 83.27 50 90.54 60 97.44 70 104.06 80 110.55 90 116.83 100 122.71 110 128.38 120 133.71 130 138.86 140 143.75 150 148.57 160 153.26 170 157.78 180 162.24 190 166.57 200 170.8 210 174.98 220 179.07 230 182.9 240 186.7 250 190.6 260 194.4 270 198.2 280 201.8 290 205.3 300 208.7 310 212.1 320 215.5 330 218.9 340 222.2 350 225.5 #CV 10 15 O.L. 20 O.L. 25 2809.43 30 2423.08 35 2152.71 40 1948.75 45 1793.03 50 1668.56 55 1571.27 60 1501.57 65 1458.05 70 1434.13 75 1422.37 80 1416.63 85 1413.68 90 1411.71 95 1410.19 100 1409.09 105 1408.14 110 1407.18 115 1406.42 120 1405.72 #End of manufacturer data file