#General information ITEM section %ITEM SERIAL NUMBER 20220900210888 Mfr serial number STN13019-10888 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 04/07/2002 PROBLEM NO PASSED YES Run number 20220900210888 #Test data Data section %DATA TEMPERATURE (C) 27 I_LEAK150V (microA) 0.1714 I_LEAK350V (microA) 0.2827 Substr Origin 276 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 288 Vdep (V) 60 R Bias Upper (MOhm) 1.58 R Bias Lower (MOhm) 1.32 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 49.04 20 69.19 30 80.8 40 90.09 50 98.63 60 106.86 70 115.2 80 123.22 90 130.86 100 138.18 110 145.18 120 151.96 130 158.55 140 165.02 150 171.4 160 177.67 170 183.9 180 190 190 196 200 202 210 207.9 220 213.7 230 219.4 240 225.2 250 230.8 260 236.3 270 241.6 280 246.9 290 252.4 300 257.5 310 262.7 320 268 330 272.7 340 277.6 350 282.7 #CV 10 15 O.L. 20 O.L. 25 2547.59 30 2198.34 35 1952.69 40 1769.79 45 1633.85 50 1537.98 55 1479.25 60 1448.31 65 1434.29 70 1428.19 75 1424.17 80 1422.54 85 1420.3 90 1419.51 95 1418.1 100 1417.3 105 1416.21 110 1415.72 115 1414.93 120 1414.28 #End of manufacturer data file