#General information ITEM section %ITEM SERIAL NUMBER 20220900210889 Mfr serial number STN13019-10889 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 04/07/2002 PROBLEM NO PASSED YES Run number 20220900210889 #Test data Data section %DATA TEMPERATURE (C) 27 I_LEAK150V (microA) 0.14183 I_LEAK350V (microA) 0.225 Substr Origin 276 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 288 Vdep (V) 60 R Bias Upper (MOhm) 1.58 R Bias Lower (MOhm) 1.32 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 42.91 20 59.53 30 68.97 40 76.47 50 83.27 60 89.74 70 96.25 80 102.82 90 109.15 100 115.19 110 120.9 120 126.42 130 131.72 140 136.86 150 141.83 160 146.67 170 151.34 180 156.01 190 160.56 200 165.07 210 169.48 220 173.83 230 177.92 240 182.4 250 186.5 260 190.5 270 194.5 280 198.4 290 202.3 300 206.2 310 210.2 320 214 330 217.7 340 221.3 350 225 #CV 10 15 O.L. 20 O.L. 25 2536.22 30 2189.57 35 1945.6 40 1763.63 45 1628.41 50 1534.06 55 1477.17 60 1448.24 65 1435.56 70 1429.72 75 1426.56 80 1424.49 85 1422.65 90 1421.63 95 1420.2 100 1418.95 105 1418.34 110 1417.3 115 1416.58 120 1415.99 #End of manufacturer data file