#General information ITEM section %ITEM SERIAL NUMBER 20220900210890 Mfr serial number STN13019-10890 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 04/07/2002 PROBLEM NO PASSED YES Run number 20220900210890 #Test data Data section %DATA TEMPERATURE (C) 27 I_LEAK150V (microA) 0.14275 I_LEAK350V (microA) 0.2247 Substr Origin 276 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 288 Vdep (V) 60 R Bias Upper (MOhm) 1.58 R Bias Lower (MOhm) 1.32 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 43.26 20 60.31 30 70.02 40 77.68 50 84.55 60 91.14 70 97.74 80 104.32 90 110.59 100 116.56 110 122.03 120 127.6 130 132.81 140 137.86 150 142.75 160 147.53 170 152.09 180 156.64 190 161.09 200 165.51 210 169.77 220 174.01 230 178.23 240 182.4 250 186.5 260 190.5 270 194.4 280 198.3 290 202.5 300 206.3 310 210.1 320 213.8 330 217.4 340 221.1 350 224.7 #CV 10 15 O.L. 20 O.L. 25 2532.58 30 2188.17 35 1945.38 40 1764.91 45 1629.94 50 1535.18 55 1477.79 60 1448.62 65 1435.27 70 1428.94 75 1425.62 80 1423.49 85 1421.66 90 1420.3 95 1419.01 100 1418.04 105 1417.01 110 1416.07 115 1415.39 120 1414.71 #End of manufacturer data file