#General information ITEM section %ITEM SERIAL NUMBER 20220900210969 Mfr serial number STN13023-10969 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 10/07/2002 PROBLEM NO PASSED YES Run number 20220900210969 #Test data Data section %DATA TEMPERATURE (C) 27 I_LEAK150V (microA) 0.10159 I_LEAK350V (microA) 0.15083 Substr Origin 288 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 290 Vdep (V) 65 R Bias Upper (MOhm) 1.51 R Bias Lower (MOhm) 1.27 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 34.92 20 47.62 30 54.43 40 59.63 50 63.96 60 68.13 70 72.58 80 77.06 90 81.18 100 85.08 110 88.68 120 92.08 130 95.37 140 98.53 150 101.59 160 104.56 170 107.38 180 110.2 190 112.96 200 115.66 210 118.33 220 120.92 230 123.46 240 125.95 250 128.44 260 130.84 270 133.18 280 135.55 290 137.83 300 140.09 310 142.3 320 144.47 330 146.62 340 148.75 350 150.83 #CV 10 15 O.L. 20 O.L. 25 2615.15 30 2257.59 35 2006.52 40 1819.25 45 1676.91 50 1570.43 55 1498.2 60 1456.83 65 1436.4 70 1427.53 75 1422.86 80 1420.48 85 1418.79 90 1417 95 1415.64 100 1414.81 105 1414.01 110 1413.12 115 1412.3 120 1411.6 #End of manufacturer data file