#General information ITEM section %ITEM SERIAL NUMBER 20220900210991 Mfr serial number STN13024-10991 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 16/07/2002 PROBLEM NO PASSED YES Run number 20220900210991 #Test data Data section %DATA TEMPERATURE (C) 27 I_LEAK150V (microA) 0.11319 I_LEAK350V (microA) 0.17126 Substr Origin 288 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 290 Vdep (V) 65 R Bias Upper (MOhm) 1.65 R Bias Lower (MOhm) 1.23 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open 383 %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 37.33 20 51.77 30 59.47 40 65.42 50 70.28 60 74.9 70 79.74 80 84.69 90 89.52 100 93.96 110 98.14 120 102.08 130 105.94 140 109.64 150 113.19 160 116.6 170 119.87 180 123.16 190 126.38 200 129.52 210 132.58 220 135.59 230 138.63 240 141.53 250 144.38 260 147.24 270 150.01 280 152.72 290 155.43 300 158.16 310 160.83 320 163.44 330 166.04 340 168.72 350 171.26 #CV 10 15 O.L. 20 O.L. 25 2602.89 30 2244.01 35 1993.21 40 1805.43 45 1664.27 50 1560.58 55 1492.11 60 1454.02 65 1435.05 70 1426.6 75 1422.65 80 1419.65 85 1418.04 90 1416.77 95 1415.29 100 1414.04 105 1413.17 110 1412.48 115 1411.57 120 1410.8 #End of manufacturer data file