#General information ITEM section %ITEM SERIAL NUMBER 20220900210998 Mfr serial number STN13024-10998 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 16/07/2002 PROBLEM NO PASSED YES Run number 20220900210998 #Test data Data section %DATA TEMPERATURE (C) 27 I_LEAK150V (microA) 0.13421 I_LEAK350V (microA) 0.2037 Substr Origin 288 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 290 Vdep (V) 65 R Bias Upper (MOhm) 1.65 R Bias Lower (MOhm) 1.23 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 43.27 20 60.36 30 69.69 40 76.84 50 82.81 60 88.47 70 94.35 80 100.25 90 105.91 100 111.22 110 116.18 120 120.9 130 125.48 140 129.93 150 134.21 160 138.39 170 142.34 180 146.28 190 150.1 200 153.88 210 157.55 220 161.16 230 164.56 240 168.21 250 171.65 260 175.06 270 178.34 280 181.7 290 185 300 188.2 310 191.5 320 194.4 330 197.7 340 200.7 350 203.7 #CV 10 15 O.L. 20 O.L. 25 2631.39 30 2268.01 35 2014.39 40 1824.34 45 1680.48 50 1573.45 55 1501.3 60 1459.77 65 1439.22 70 1429.48 75 1424.94 80 1422.42 85 1420.2 90 1418.6 95 1417.73 100 1416.22 105 1415.12 110 1414.35 115 1413.89 120 1412.93 #End of manufacturer data file