#General information ITEM section %ITEM SERIAL NUMBER 20220900211011 Mfr serial number STN13024-11011 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 16/07/2002 PROBLEM NO PASSED YES Run number 20220900211011 #Test data Data section %DATA TEMPERATURE (C) 27 I_LEAK150V (microA) 0.11212 I_LEAK350V (microA) 0.17235 Substr Origin 288 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 289 Vdep (V) 65 R Bias Upper (MOhm) 1.65 R Bias Lower (MOhm) 1.23 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 35.93 20 49.69 30 57.17 40 62.93 50 67.97 60 72.96 70 77.97 80 82.95 90 87.83 100 92.42 110 96.73 120 100.79 130 104.73 140 108.58 150 112.12 160 115.81 170 119.26 180 122.66 190 125.96 200 129.22 210 132.39 220 135.59 230 138.7 240 141.73 250 144.72 260 147.71 270 150.55 280 153.38 290 156.17 300 159.01 310 161.73 320 164.37 330 167.05 340 169.79 350 172.35 #CV 10 15 O.L. 20 O.L. 25 2591.9 30 2236.57 35 1987.5 40 1801.21 45 1661.02 50 1559.04 55 1492.22 60 1455.74 65 1438.02 70 1429.73 75 1425.89 80 1423.26 85 1421.61 90 1420 95 1418.95 100 1417.77 105 1416.64 110 1416.18 115 1415.34 120 1414.39 #End of manufacturer data file