#General information ITEM section %ITEM SERIAL NUMBER 20220900211327 Mfr serial number STN13242-11327 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 05/08/2002 PROBLEM NO PASSED YES Run number 20220900211327 #Test data Data section %DATA TEMPERATURE (C) 27 I_LEAK150V (microA) 0.17105 I_LEAK350V (microA) 0.2583 Substr Origin 293 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 292 Vdep (V) 80 R Bias Upper (MOhm) 1.37 R Bias Lower (MOhm) 1.23 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 50.85 20 73.22 30 85.41 40 95.12 50 104.5 60 112.48 70 119.57 80 126.49 90 133.39 100 140.13 110 146.55 120 152.83 130 159.22 140 165.24 150 171.05 160 176.46 170 182.3 180 187.4 190 192.9 200 198 210 202.8 220 207.6 230 212.1 240 216.5 250 220.9 260 225.2 270 229.2 280 233.1 290 237 300 240.7 310 244.5 320 248 330 251.6 340 254.9 350 258.3 #CV 10 15 O.L. 20 O.L. 25 O.L. 30 2628.01 35 2327.36 40 2104 45 1929.87 50 1791.56 55 1678.64 60 1588.61 65 1520.38 70 1471.95 75 1442.24 80 1424.36 85 1414.8 90 1410.34 95 1405.81 100 1404.15 105 1402.67 110 1405.32 115 1399.66 120 1384.85 #End of manufacturer data file