#General information ITEM section %ITEM SERIAL NUMBER 20220900211620 Mfr serial number STN13240-11620 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 22/08/2002 PROBLEM NO PASSED YES Run number 20220900211620 #Test data Data section %DATA TEMPERATURE (C) 26 I_LEAK150V (microA) 0.14182 I_LEAK350V (microA) 0.2087 Substr Origin 293 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 287 Vdep (V) 75 R Bias Upper (MOhm) 1.54 R Bias Lower (MOhm) 1.3 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 46.65 20 64.81 30 75.28 40 83.47 50 90.23 60 96.42 70 102.57 80 108.43 90 113.99 100 119.27 110 124.1 120 128.75 130 133.36 140 137.6 150 141.82 160 145.83 170 149.85 180 153.67 190 157.4 200 161.06 210 164.72 220 168.26 230 171.68 240 175.06 250 178.37 260 181.7 270 184.9 280 188 290 191.1 300 194.2 310 197.3 320 200.1 330 203 340 205.9 350 208.7 #CV 10 15 O.L. 20 O.L. 25 2913.71 30 2513.46 35 2233.79 40 2023.99 45 1862 50 1732.61 55 1628.19 60 1547.92 65 1490.91 70 1454.56 75 1433.65 80 1422.51 85 1416.86 90 1413.82 95 1411.92 100 1410.53 105 1409.4 110 1408.56 115 1407.65 120 1406.92 #End of manufacturer data file