#General information ITEM section %ITEM SERIAL NUMBER 20220900212517 Mfr serial number STN13612-12517 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 21/10/2002 PROBLEM NO PASSED YES Run number 20220900212517 #Test data Data section %DATA TEMPERATURE (C) 26 I_LEAK150V (microA) 0.14752 I_LEAK350V (microA) 0.2168 Substr Origin 321 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 291 Vdep (V) 100 R Bias Upper (MOhm) 1.49 R Bias Lower (MOhm) 1.34 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 46.2 20 66.65 30 78.15 40 87 50 94.84 60 101.61 70 107.98 80 113.51 90 118.84 100 123.8 110 128.95 120 133.87 130 138.63 140 143.12 150 147.52 160 151.67 170 155.61 180 159.81 190 163.61 200 167.45 210 171.13 220 174.75 230 178.29 240 181.5 250 185 260 188.3 270 191.6 280 194.9 290 198.2 300 201.3 310 204.6 320 207.6 330 210.7 340 213.8 350 216.8 #CV 10 15 O.L. 20 O.L. 25 O.L. 30 O.L. 35 2773.06 40 2507.79 45 2300.15 50 2133.09 55 1996.32 60 1882.09 65 1784.12 70 1699.9 75 1626.88 80 1564.39 85 1513.05 90 1473.56 95 1446.14 100 1428.95 105 1419.15 110 1413.55 115 1410.75 120 1409.01 #End of manufacturer data file