#General information ITEM section %ITEM SERIAL NUMBER 20220900212521 Mfr serial number STN13612-12521 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 21/10/2002 PROBLEM NO PASSED YES Run number 20220900212521 #Test data Data section %DATA TEMPERATURE (C) 26 I_LEAK150V (microA) 0.14839 I_LEAK350V (microA) 0.2183 Substr Origin 321 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 290 Vdep (V) 100 R Bias Upper (MOhm) 1.49 R Bias Lower (MOhm) 1.34 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 46.27 20 66.8 30 78.28 40 87.27 50 95.28 60 102.46 70 108.88 80 114.65 90 119.95 100 124.98 110 130.06 120 134.92 130 139.58 140 144.06 150 148.39 160 152.53 170 156.6 180 160.57 190 164.37 200 168.16 210 171.86 220 175.46 230 178.9 240 182.4 250 185.8 260 189.2 270 192.5 280 195.8 290 199.1 300 202.4 310 205.6 320 208.7 330 211.9 340 215.1 350 218.3 #CV 10 15 O.L. 20 O.L. 25 O.L. 30 O.L. 35 2767.02 40 2502.65 45 2296.59 50 2129.72 55 1993.2 60 1879.21 65 1781.45 70 1696.95 75 1624.61 80 1562.23 85 1511.69 90 1473.51 95 1447.8 100 1431.05 105 1421.95 110 1416.79 115 1413.81 120 1411.88 #End of manufacturer data file