#General information ITEM section %ITEM SERIAL NUMBER 20220900212531 Mfr serial number STN13612-12531 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 21/10/2002 PROBLEM NO PASSED YES Run number 20220900212531 #Test data Data section %DATA TEMPERATURE (C) 26 I_LEAK150V (microA) 0.15261 I_LEAK350V (microA) 0.2237 Substr Origin 321 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 290 Vdep (V) 85 R Bias Upper (MOhm) 1.49 R Bias Lower (MOhm) 1.34 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 49.37 20 69.7 30 81.06 40 89.86 50 97.36 60 104.32 70 110.83 80 116.81 90 122.58 100 128.17 110 133.54 120 138.52 130 143.49 140 148.12 150 152.61 160 156.94 170 161.16 180 165.3 190 169.22 200 173.16 210 176.95 220 180.5 230 184.1 240 187.7 250 191.2 260 194.7 270 198.1 280 201.4 290 204.7 300 208 310 211.2 320 214.4 330 217.6 340 220.7 350 223.7 #CV 10 15 O.L. 20 O.L. 25 O.L. 30 2844.18 35 2522.52 40 2283.67 45 2095.15 50 1945.87 55 1822.66 60 1719.69 65 1632.77 70 1560.99 75 1505.23 80 1465.71 85 1440.61 90 1426.02 95 1418.2 100 1414.04 105 1411.45 110 1409.79 115 1408.77 120 1407.91 #End of manufacturer data file