#General information ITEM section %ITEM SERIAL NUMBER 20220900212582 Mfr serial number STN13467-12582 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 21/10/2002 PROBLEM NO PASSED YES Run number 20220900212582 #Test data Data section %DATA TEMPERATURE (C) 24 I_LEAK150V (microA) 0.10736 I_LEAK350V (microA) 0.16294 Substr Origin 305 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 290 Vdep (V) 75 R Bias Upper (MOhm) 1.51 R Bias Lower (MOhm) 1.29 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 34.69 20 48.02 30 55.39 40 61.34 50 66.58 60 71.47 70 76.09 80 80.62 90 85.01 100 89.19 110 93.1 120 96.89 130 100.57 140 104.07 150 107.36 160 110.8 170 114.06 180 117.19 190 120.25 200 123.27 210 126.29 220 129.09 230 131.95 240 134.74 250 137.49 260 140.24 270 142.91 280 145.51 290 148.12 300 150.68 310 153.19 320 155.66 330 158.1 340 160.57 350 162.94 #CV 10 15 O.L. 20 O.L. 25 2880.12 30 2483.02 35 2204.85 40 1996.56 45 1836.69 50 1710.14 55 1610.43 60 1535.73 65 1484.65 70 1453.16 75 1434.99 80 1425.19 85 1420.17 90 1417.38 95 1415.63 100 1414.15 105 1413.02 110 1412.22 115 1411.27 120 1410.61 #End of manufacturer data file