#General information ITEM section %ITEM SERIAL NUMBER 20220900212691 Mfr serial number STN13602-12691 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 30/10/2002 PROBLEM NO PASSED YES Run number 20220900212691 #Test data Data section %DATA TEMPERATURE (C) 24 I_LEAK150V (microA) 0.13449 I_LEAK350V (microA) 0.2008 Substr Origin 317 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 289 Vdep (V) 75 R Bias Upper (MOhm) 1.32 R Bias Lower (MOhm) 1.16 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 42.58 20 59.68 30 68.94 40 77.2 50 84.22 60 90.22 70 95.77 80 101.32 90 106.68 100 111.75 110 116.61 120 121.29 130 125.88 140 130.26 150 134.49 160 138.58 170 142.61 180 146.46 190 150.22 200 153.9 210 157.53 220 161.04 230 164.47 240 167.83 250 171.14 260 174.42 270 177.61 280 180.5 290 183.8 300 186.9 310 189.9 320 192.8 330 195.5 340 198.2 350 200.8 #CV 10 15 O.L. 20 O.L. 25 2988.01 30 2573.33 35 2282.69 40 2065.29 45 1897 50 1763.17 55 1655.13 60 1569.78 65 1506.77 70 1464.85 75 1439.8 80 1426.42 85 1419.82 90 1416.43 95 1414.45 100 1413.08 105 1412.09 110 1411.34 115 1410.56 120 1409.85 #End of manufacturer data file