#General information ITEM section %ITEM SERIAL NUMBER 20220900212721 Mfr serial number STN13606-12721 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 30/10/2002 PROBLEM NO PASSED YES Run number 20220900212721 #Test data Data section %DATA TEMPERATURE (C) 24 I_LEAK150V (microA) 0.09084 I_LEAK350V (microA) 0.12971 Substr Origin 318 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 289 Vdep (V) 95 R Bias Upper (MOhm) 1.64 R Bias Lower (MOhm) 1.5 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 30.3 20 42.01 30 48.99 40 54.89 50 59.57 60 63.49 70 66.9 80 70.03 90 73.21 100 76.42 110 79.64 120 82.65 130 85.57 140 88.17 150 90.84 160 93.33 170 95.75 180 98.09 190 100.3 200 102.48 210 104.65 220 106.66 230 108.66 240 110.6 250 112.52 260 114.41 270 116.24 280 118.02 290 119.76 300 121.51 310 123.21 320 124.87 330 126.5 340 128.15 350 129.71 #CV 10 15 O.L. 20 O.L. 25 O.L. 30 2986.06 35 2650.52 40 2398.88 45 2204.59 50 2048.6 55 1920.02 60 1812.34 65 1719.78 70 1640.6 75 1573.42 80 1519.02 85 1478.52 90 1450.98 95 1433.69 100 1423.72 105 1418.15 110 1415.2 115 1413.42 120 1412.14 #End of manufacturer data file