#General information ITEM section %ITEM SERIAL NUMBER 20220900213082 Mfr serial number STN13771-13082 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 21/11/2002 PROBLEM NO PASSED YES Run number 20220900213082 #Test data Data section %DATA TEMPERATURE (C) 26 I_LEAK150V (microA) 0.08427 I_LEAK350V (microA) 0.12239 Substr Origin 328 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 293 Vdep (V) 75 R Bias Upper (MOhm) 1.63 R Bias Lower (MOhm) 1.2 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 30.12 20 40.91 30 46.73 40 51.22 50 55.01 60 58.42 70 61.74 80 64.99 90 68.2 100 71.25 110 74.08 120 76.77 130 79.41 140 81.9 150 84.27 160 86.62 170 88.89 180 91.11 190 93.22 200 95.29 210 97.41 220 99.37 230 101.37 240 103.26 250 105.18 260 107.07 270 108.89 280 110.61 290 112.4 300 114.13 310 115.85 320 117.51 330 119.16 340 120.8 350 122.39 #CV 10 15 O.L. 20 O.L. 25 2937.9 30 2534.47 35 2251.71 40 2039.6 45 1876.43 50 1745.91 55 1640.04 60 1557.07 65 1496.59 70 1456.75 75 1432.88 80 1419.88 85 1413 90 1409.4 95 1407.28 100 1405.81 105 1404.62 110 1403.67 115 1402.82 120 1402.02 #End of manufacturer data file