Sensors for irradiation in April 2001/April/05 Summary of microdischarge onset voltages. Ham-F: I-V measured as "bare" sensor, al metal floating KEK-G: I-V measured as "irradiation" assembly, al metal bonded together and grounded (=strip bias) KEK-F: I-V measured as "irradiation" assembly, al metal bonded together but floating (=disconnected from strip bias) KEK measurement: 26 deg.C, 6 min./0-500V Sensor id Onset voltage [V] <100> Ham-F KEK-G KEK-F Comment 20220900200729 210 230 --- consistent 20220900200737 --- --- --- consistent, larger slope 20220900200751 120 360 --- >100V better 20220900200834 280 280 --- consistent 20220900200921 270 260 --- consistent 20220900200969 330 >500 450 >100V better <111> 20220900201331 330 480 480 >100V better 20220900201389 300 >500 >500 >200V better 20220900201416 230 >500 >500 >200V better 20220900201467 210 >500 >500 >200V better