From: KEKVAX::TERADA 29-JUL-1996 14:53:46.77 To: OHSUGI,IWATAY CC: KONDO,UNNO,IWASAKIH,KOHRIKI,TERADA Subj: Proton fluence calculation I have finished the flux calculation for the last proton irradiation at KEK-PS. The results is; For Low dose run 3.81 x 10**13 protons/cm**2 (for CDF silicon sample) For High dose run 1.83 x 10**14 protons/cm**2 (for glues etc.) Overall error for the measurement is 10% (conservative), in which dominant sources are as follows; Statistics: 2.8 % Calibration: 5 % Production Crosssection: 5 % Uniformity of the low dose exposure was very good. It was better than +/- 3% over the silicon area. Temperature History of the silicon is the following; from to time period temp(c) 1996-6-21 10:19 16:32 6h23m 31.9 1996-6-21 16:29 7-8 9:00 16d16h31m 31.1 1996-7-8 9:00 7-11 14:00 3d5h 29.0 1996-7-11 14:00 14:20 20m 25 1996-7-11 14:20 after -20 Susumu Terada (x5355)