#General information ITEM section %ITEM SERIAL NUMBER 20220900203862 Mfr serial number STN11622-03862 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 23/07/2001 PROBLEM NO PASSED YES Run number 20220900203862 #Test data Data section %DATA TEMPERATURE (C) 25 I_LEAK150V (microA) 0.16935 I_LEAK350V (microA) 0.2623 Substr Origin 110 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 286 Vdep (V) 65 R Bias Upper (MOhm) 1.55 R Bias Lower (MOhm) 1.39 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 56.45 20 80.15 30 90.45 40 99.17 50 106.6 60 114.15 70 121.5 80 128.31 90 134.65 100 140.82 110 146.69 120 152.3 130 158.19 140 163.8 150 169.35 160 174.77 170 180 180 185.3 190 190.5 200 195.8 210 201 220 206 230 211.1 240 216.2 250 220.9 260 225.1 270 229.6 280 234.3 290 238.6 300 243 310 247.3 320 251.3 330 255.1 340 258.7 350 262.3 #CV 10 15 O.L. 20 O.L. 25 2626.51 30 2266.6 35 2015.18 40 1824.29 45 1678.32 50 1567.24 55 1490.63 60 1450.04 65 1432.96 70 1426.09 75 1422.63 80 1420.45 85 1418.71 90 1417.4 95 1416.32 100 1415.35 105 1414.53 110 1414.04 115 1413.32 120 1412.69 #End of manufacturer data file