#General information ITEM section %ITEM SERIAL NUMBER 20220900205809 Mfr serial number STN12036-05809 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 30/10/2001 PROBLEM NO PASSED YES Run number 20220900205809 #Test data Data section %DATA TEMPERATURE (C) 27 I_LEAK150V (microA) 0.14182 I_LEAK350V (microA) 0.2264 Substr Origin 175 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 291 Vdep (V) 65 R Bias Upper (MOhm) 1.46 R Bias Lower (MOhm) 1.29 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 43.28 20 61.62 30 71.42 40 78.88 50 85.55 60 92.25 70 99.03 80 105.34 90 111.25 100 116.86 110 122.11 120 127.23 130 132.31 140 137.1 150 141.82 160 146.15 170 150.97 180 155.38 190 159.71 200 164.02 210 168.34 220 172.53 230 176.66 240 180.8 250 184.7 260 188.7 270 192.6 280 196.5 290 200.3 300 204.3 310 208.2 320 212.3 330 216.5 340 221.1 350 226.4 #CV 10 15 O.L. 20 O.L. 25 2608.01 30 2247.59 35 1996.04 40 1808.1 45 1666.09 50 1561.17 55 1492.12 60 1454.31 65 1436.32 70 1428.53 75 1424.56 80 1421.99 85 1420.19 90 1418.9 95 1417.27 100 1416.35 105 1415.25 110 1414.17 115 1413.64 120 1412.77 #End of manufacturer data file