#General information ITEM section %ITEM SERIAL NUMBER 20220900206183 Mfr serial number STN12030-06183 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 12/11/2001 PROBLEM NO PASSED YES Run number 20220900206183 #Test data Data section %DATA TEMPERATURE (C) 26 I_LEAK150V (microA) 0.1213 I_LEAK350V (microA) 0.185 Substr Origin 158 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 292 Vdep (V) 70 R Bias Upper (MOhm) 1.29 R Bias Lower (MOhm) 1.03 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 38.77 20 51.17 30 58.84 40 64.96 50 70.47 60 75.94 70 81.78 80 87.82 90 93.61 100 98.94 110 103.81 120 108.57 130 113.01 140 117.22 150 121.3 160 125.26 170 129.07 180 132.8 190 136.43 200 139.99 210 143.46 220 146.87 230 150.18 240 153.41 250 156.57 260 159.73 270 162.8 280 165.78 290 168.68 300 171.6 310 174.45 320 177.16 330 179.92 340 182.4 350 185 #CV 10 15 O.L. 20 O.L. 25 2814.55 30 2424.1 35 2151.88 40 1948.11 45 1791.32 50 1666.96 55 1568.28 60 1496.53 65 1450.9 70 1426.25 75 1414.67 80 1409.09 85 1406.04 90 1404.17 95 1402.78 100 1401.55 105 1400.7 110 1399.91 115 1399.14 120 1398.45 #End of manufacturer data file