#General information ITEM section %ITEM SERIAL NUMBER 20220900208282 Mfr serial number STN12613-08282 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 26/02/2002 PROBLEM NO PASSED YES Run number 20220900208282 #Test data Data section %DATA TEMPERATURE (C) 26 I_LEAK150V (microA) 0.08383 I_LEAK350V (microA) 0.12576 Substr Origin 246 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 285 Vdep (V) 60 R Bias Upper (MOhm) 1.56 R Bias Lower (MOhm) 1.27 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 28.14 20 38.23 30 43.44 40 47.45 50 51.09 60 54.82 70 58.72 80 62.48 90 66.04 100 69.39 110 72.54 120 75.5 130 78.39 140 81.16 150 83.83 160 86.43 170 88.87 180 91.33 190 93.69 200 96.06 210 98.31 220 100.56 230 102.73 240 104.89 250 106.98 260 109.05 270 111.01 280 112.99 290 114.97 300 116.87 310 118.71 320 120.5 330 122.29 340 124.04 350 125.76 #CV 10 15 O.L. 20 2919.46 25 2406.28 30 2077.62 35 1849.19 40 1685.21 45 1569.69 50 1498.1 55 1460.26 60 1443.42 65 1436.24 70 1432.62 75 1430.51 80 1428.74 85 1427.28 90 1426.2 95 1425.23 100 1424.19 105 1423.33 110 1422.49 115 1421.85 120 1421.26 #End of manufacturer data file