#General information ITEM section %ITEM SERIAL NUMBER 20220900208287 Mfr serial number STN12613-08287 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 26/02/2002 PROBLEM NO PASSED YES Run number 20220900208287 #Test data Data section %DATA TEMPERATURE (C) 26 I_LEAK150V (microA) 0.07328 I_LEAK350V (microA) 0.11016 Substr Origin 246 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 285 Vdep (V) 55 R Bias Upper (MOhm) 1.56 R Bias Lower (MOhm) 1.27 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 8.823 20 31.87 30 36.2 40 39.83 50 43.37 60 46.95 70 50.46 80 53.87 90 57.08 100 60.12 110 62.99 120 65.7 130 68.33 140 70.83 150 73.28 160 75.6 170 77.83 180 80.04 190 82.19 200 84.29 210 86.34 220 88.34 230 90.26 240 92.19 250 94.03 260 95.86 270 97.54 280 99.26 290 100.89 300 102.53 310 104.11 320 105.65 330 107.16 340 108.67 350 110.16 #CV 10 15 O.L. 20 2628.72 25 2172.22 30 1880.9 35 1689.39 40 1569.25 45 1500.86 50 1466.36 55 1450.64 60 1443.36 65 1439.57 70 1437.27 75 1435.59 80 1434.16 85 1433 90 1431.96 95 1430.98 100 1430.11 105 1429.21 110 1428.61 115 1427.86 120 1427.18 #End of manufacturer data file