#General information ITEM section %ITEM SERIAL NUMBER 20220900209976 Mfr serial number STN12913-09976 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 28/05/2002 PROBLEM NO PASSED YES Run number 20220900209976 #Test data Data section %DATA TEMPERATURE (C) 27 I_LEAK150V (microA) 0.10422 I_LEAK350V (microA) 0.15093 Substr Origin 261 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 290 Vdep (V) 75 R Bias Upper (MOhm) 1.42 R Bias Lower (MOhm) 1.28 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 36.27 20 49.13 30 56.21 40 61.75 50 66.59 60 71.12 70 75.51 80 79.82 90 83.93 100 87.82 110 91.43 120 94.85 130 98.09 140 101.21 150 104.22 160 107.11 170 109.83 180 112.55 190 115.2 200 117.8 210 120.31 220 122.77 230 125.16 240 127.55 250 129.85 260 132.12 270 134.32 280 136.52 290 138.69 300 140.86 310 142.96 320 145.05 330 147.07 340 149.03 350 150.93 #CV 10 15 O.L. 20 O.L. 25 2920.59 30 2515.83 35 2232.84 40 2020.39 45 1858.16 50 1727.94 55 1624.39 60 1545.63 65 1490.4 70 1454.87 75 1433.77 80 1422.23 85 1416.28 90 1413.04 95 1411.16 100 1409.74 105 1408.64 110 1407.66 115 1406.97 120 1406.21 #End of manufacturer data file