#General information ITEM section %ITEM SERIAL NUMBER 20220900211339 Mfr serial number STN13242-11339 #Test information Test section %TEST TEST DATE (DD/MM/YYYY) 05/08/2002 PROBLEM NO PASSED YES Run number 20220900211339 #Test data Data section %DATA TEMPERATURE (C) 27 I_LEAK150V (microA) 0.16392 I_LEAK350V (microA) 0.2582 Substr Origin 291 Substr Orient 111 Substr R Upper (kOhm.cm) 8 Substr R Lower (kOhm.cm) 4 Thickness (micron) 291 Vdep (V) 70 R Bias Upper (MOhm) 1.37 R Bias Lower (MOhm) 1.23 #Comment section %COMMENT #Defects section %DEFECT #DEFECT NAME Implant-Open Implant-Short Oxide-Punchthrough Pinhole Short Open %WEBLINK #DESCRIPTION URL #IV raw data Raw data section %RAWDATA DATA #IV 10 48.12 20 67.76 30 78.69 40 87.2 50 94.97 60 102.62 70 110.26 80 117.85 90 125 100 132.07 110 138.83 120 145.25 130 151.66 140 157.83 150 163.92 160 169.67 170 175.56 180 181.1 190 186.9 200 192.4 210 197.8 220 202.8 230 207.7 240 212.5 250 217.1 260 222.1 270 226.5 280 230.7 290 234.9 300 239 310 242.9 320 247 330 250.7 340 254.4 350 258.2 #CV 10 15 O.L. 20 O.L. 25 2725.59 30 2347.89 35 2084.55 40 1887.55 45 1736.49 50 1619.06 55 1532.5 60 1476.07 65 1443.84 70 1427.81 75 1420.24 80 1416.36 85 1413.79 90 1412.01 95 1410.73 100 1409.56 105 1408.36 110 1407.46 115 1406.64 120 1406.04 #End of manufacturer data file